Acrel ADW300 IOT Wireless 3 Phase Smart Energy Meter
Measurement: 3-phase Active Power, Reactive Power, Current, Voltage, Harmonic and etc.Rated Current: 3x1(6)A AC (via CTs)Rated Voltage: Up to 3x660~792Vac L-LCommunication: RS485,4G,WIFI,LoRa,LorawanHMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etcApplication Scenario: Building, Factory, Smart Grids, DB Room and etcStandard&Certificate: CE; IEC; LVD
Acrel AIM-M200 Medical intelligent insulation monitor
Insulation monitoring and alarm for medical IT systems
Fault Locator (Work with insulation fault locator)
Real-time monitor the line disconnection fault
Relay output, LED indicator and other fault indication
Event record
RS485(MODBUS-RTU) + CAN
Acrel AIM-M10 Medical Intelligent Insulation Monitor
Insulation monitoring for medical IT systems; Fault alarm
Real-time monitor the line disconnection fault
Relay output, LED indicator and other fault indication
Modbus-RTU communication
Event Record
DC 24V Power Supply (Power for external alarm and display instrument)
Acrel ATE400 Tied Type Passive Wireless Temperature Sensor
Range of Measurement: -50℃~+125℃Communication: GFSK Wireless CommunicationApplication: Switch-gear, Bus-bar, Bus duct, Electric contact, Cable joint, Rain main unit and etcInstallation: Alloy Sheet FixedProtection Level: IP68 (Optional)Power Supply: CT Sensing PowerStandard&Certificate: CE
Acrel ATE200 Belt Wireless Temperature Sensor
Range of Measurement: -50℃~+125℃Communication: GFSK Wireless CommunicationApplication: Switch-gear, Bus-bar, Bus duct, Electric contact, Cable joint, Rain main unit and etcInstallation: BeltProtection Level: IP68 (Optional)Power Supply: BatteryStandard&Certificate: CE
Acrel AMC16MA Data Center Multi-Channel Energy Meter
Input voltage AC220V, input current AC 5A(self-setting transformer ratio)
Outlet current transformer ratio AC100A/20mA
2 inlet testing and 36 single phase(or 12 3-phase) outlet testing,1 switching output
Communication protocol: RS485 port Modbus/RTU protocol
Power supply:AC220V
Acrel AGF-MxT DC Multi-Circuits Monitoring Device for PV Combiner Box
Measurement: DC Current of up to 24 Circuits (with Hall Sensors); 1000v DC Voltage of Busbar
Communication: RS485 (MODBUS-RTU)
Application: Paired with PV Combiner Box for DC Multi-circuits Monitoring
Temperature Monitoring: Inner Temperature of PV Combiner Box
DI Function: 3-channel Digital Input
Display: LCD Display(Optional)
Installation: 35mm DIN Rail (Main Body); Perforation (Cable)
Power Supply: 1000V DC or 1500V DC
Standard&Certificate: CE;LVD;EMC
Acrel ACR10R-DxxTEx Bidirectional Three-phase Reflux Monitoring Energy Meter
● Measurement: 3-phase Active Power, Reactive Power, Current, Voltage and etc
● Current Rating: up to 300A (with CTs); up to 20000A (with Rogowski Coil)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Display
● Dimension: 54*64*84mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE
Acrel ACR10R-DxxT Bidirectional Single-phase Reflux Monitoring Energy Meter
● Measurement: 1-phase Active Power, Reactive Power, Current, Voltage and etc
● Current Rating: up to 300A (paired with external CTs)
● Communication: RS485 (MODBUS-RTU)
● Application: Using in distributed Solar PV and Anti-reflux Inverter
● Display: LCD Dispaly
● Dimension: 54*74*85mm (L*W*H)
● Installation: 35mm DIN Rail
● Power Supply: 85~265V AC or 100~350V DC
● Standard&Certificate: CE