Acrel AKH-0.66-III series square closed type current transformer
Rated Voltage: 660V AC
Accuracy: Class 0.2/Class 0.5
Primary current input: 200~6300A AC
Application: On Busbar or Cable
Rated frequency: 50-60Hz
Installation: Fixed by Sheet Metal/Fixed by Clutch Cover/35mm DIN Rail
Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
Acrel BM200 series signal isolation barrier
Input type: Current/Voltage/Thermal resistance Pt100/Resistance/Thermocouple
Transmission accuracy: 0.2%
Input: 0~20mA /4~20mA ,0~5V /0~10V /1~5V (Distribution voltage: 12V/20mA) PT100 /0~10K
Output: 0~20mA /4~20mA , 0~5V /1~5V , 0~10V
Power Supply: 20~35V DC
Response Time: 5ms to reach 90% of final value
Installation: DIN Rail
Standard&Certificate: CE
Acrel BM100 series signal isolator
Input type: Current/Voltage/Thermal resistance Pt100/Resistance
Transmission accuracy: 0.2%
Input signal: DC 0~20mA /4~20mA ,DC 0~5V /1~5V /0~10V, Pt100 ,0~10KΩ
Output signal: DC 0~20mA /4~20mA ,DC 0~5V /1~5V ,DC 0~10V /2~10V
Power supply: 20~35V DC or 85~265V AC/DC
Response time: 5ms to reach 90% of final value
Installation: DIN Rail
Standard&Certificate: CE
Acrel BM series analog signal isolator
Input type: Current/Voltage/Thermocouple/Thermal resistance PT100/2-wire or 3-wire RTD Pt100
Input:AC0~1/5V,0-125/250/450V,DC4-20mA,0-20/4-20mA,0-1/0-20/4-20mA,0-5/0-10V,PT100,0-100/1K/5K/10KΩ,0-35Ω potentiometer
Output: DC4-20mA, 4-20mA, 0~5/0~10V, 4-20mA/0~5V, 2 channels 4-20mA, 2 channels 2-20mA
Auxiliary Supply: 24VDC or 110/220V AC/DC
Isolation voltage:2kV
Installation:35mm din rail
Standard&Certificate: CE
Acrel BD-AV AC 0-500V input Voltage Transducer
● Measurement: 1-phase DC Voltage
● Accuracy: Class 0.5
● Input: AC 0-100/300/500V
● Output: 4~20mA/0~20mA DC
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V DC
● Wiring: 1-phase 2-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
Acrel BD-F 3P4W AC Frequency Transducer
● Measurement: 3-phase AC Frequency (Range: 45~50~55Hz)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
Acrel BD-PF 3P4W AC Power Factor Transducer
● Measurement: 3-phase AC Power Factor (Range: 0~1)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
Acrel BD-4P/Q/I 3P4W AC Active&Reactive Power Transducer
● Measurement: 3-phase AC Active&Reactive Power (Range: -866~+866W)
● Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
● Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
● Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE