Product Category

List Name
There are many variations of passages of Lorem Ipsum available, but the majority have suffered alteration in some form
Acrel  BA10-AI/I AC 0-50A input Current Transducer
Acrel BA10-AI/I AC 0-50A input Current Transducer
   Input: 0~(8~50)A AC  Output: 4~20mA/0~20mA DC  Power Supply: 12V/24V DC  Perforation Hole Size: φ10mm  Applicaiton: Paired with PLC for Industrial Automation  Accuracy: Class 0.5  Response Time: ≤350ms  Installation: 35mm DIN Rail/Screw fixed  Standard&Certificate: CE; TüV
Acrel  BA05-AI/I AC 0-10A input Current Transducer
Acrel BA05-AI/I AC 0-10A input Current Transducer
  ● Input: 0~(0.5~10)A AC ● Output: 4~20mA/0~20mA DC ● Power Supply: 12V/24V DC ● Perforation Hole Size: φ5mm ● Applicaiton: Paired with PLC for Industrial Automation ● Accuracy: Class 0.5 ● Response Time: ≤350ms ● Installation: 35mm DIN Rail/Screw fixed ● Standard&Certificate: CE; TüV  
Acrel AKH-0.66/K Square Split Core Current Transformer
Acrel AKH-0.66/K Square Split Core Current Transformer
    Measurement:Alternating Current (AC) Accuracy: Class 0.2/Class 0.5/Class 1.0 Primary Current Input:20~5000A AC Rated Voltage:660V AC Rated Frequency:50~60Hz Ambient air temperature:-30℃-70℃ Standard&Certificate: IEC/EN61869-1;IEC/EN61869-2;CE
Acrel AC/DC 0-1500A Open-loop Hall Effect Transducer AHKC-EKC
Acrel AC/DC 0-1500A Open-loop Hall Effect Transducer AHKC-EKC
     Rated Input: 0~±1500A DC or 0~1500A AC  Rated Output: 0~±5/±4Vdc  Aperture: φ55mm  Power Supply: ±12~±15Vdc  Accuracy: Class 1.0  Response Time: ≤5us  Installation: Clamp on (Split-core) measuring cable and screw fixed on panel  Standard&Certificate: CE; IEC; LVD
Acrel AC/DC 0-1000A Open-loop Hall Effect Transducer AHKC-EKB
Acrel AC/DC 0-1000A Open-loop Hall Effect Transducer AHKC-EKB
     Rated Input: 0~±1000A DC or 0~1000A AC  Rated Output: 0~±5/±4Vdc  Aperture: φ40mm  Power Supply: ±12~±15Vdc  Accuracy: Class 1.0  Response Time: ≤5us  Installation: Clamp on (Split-core) measuring cable and screw fixed on panel  Standard&Certificate: CE; IEC; LVD
Acrel AHKC-EKA AC/DC 0-500A Open-loop Hall Effect Transducer
Acrel AHKC-EKA AC/DC 0-500A Open-loop Hall Effect Transducer
     Rated Input: 0~±500A DC or 0~500A AC  Rated Output: 0~±5/±4Vdc  Aperture: φ20mm  Power Supply: ±12~±15Vdc  Accuracy: Class 1.0  Response Time: ≤5us  Installation: Clamp on (Split-core) measuring cable and screw fixed on panel  Standard&Certificate: CE; IEC; LVD
Acrel AKH-0.66 K-50 Series Split Core Current Transformer
Acrel AKH-0.66 K-50 Series Split Core Current Transformer
    Rated voltage: AC 0.66kV Rated Frequency:50-60Hz Environment Temperature:-30~70℃ Altitude: <3000m
Acrel AKH-0.66 K-36 Series Split Core Current Transformer
Acrel AKH-0.66 K-36 Series Split Core Current Transformer
    Rated voltage: AC 0.66kV Rated Frequency:50-60Hz Environment Temperature:-30~70℃ Altitude: <3000m
Acrel AKH-0.66 K-10 Series Split Core Current Transformer
Acrel AKH-0.66 K-10 Series Split Core Current Transformer
    Rated voltage: AC 0.66kV Rated Frequency:50-60Hz Environment Temperature:-30~70℃ Altitude: <3000m
Acrel AKH-0.66/K Split Core Current Transformer Low Voltage
Acrel AKH-0.66/K Split Core Current Transformer Low Voltage
    Rated voltage: AC 0.66kV Rated Frequency:50-60Hz Environment Temperature:-30~70℃ Altitude: <3000m
Acrel AKH-0.66-I Closed Type Measuring Current Transformer
Acrel AKH-0.66-I Closed Type Measuring Current Transformer
    Rated voltage: AC 0.66kV Rated Frequency:50-60Hz Environment Temperature:-30~70℃ Altitude: <3000m
Home  >  Products  >  Power Sensor