Acrel ADL200N-CT/DXX Din Rail Zero Export Smart Electricity Meter for Inverter
Rated voltage:AC230V
Input current:80A, 120A, 200A, 300A
Frequency:45~65Hz
Measurement: 1 phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
Communication: RS485(Modbus-RTU)
Communication address range:Modbus RTU:1~ 247
Certificate:CE
Acrel ADL200N-CT/DXX Single Phase Din Rail Multifunction Meter with CTs
Rated voltage:AC230V
Input current:80A, 120A, 200A, 300A
Frequency:45~65Hz
Measurement: 1 phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
Communication: RS485(Modbus-RTU)
Communication address range:Modbus RTU:1~ 247
Certificate:CE
Acrel ADW300 IOT Wireless 3 Phase Energy Meter by Rogowski Coil Access
Measurement: 3-phase Active Power, Reactive Power, Current, Voltage, Harmonic and etc.Rated Current: 3x200mV AC (via Rogowski Coil)Rated Voltage: Up to 3x660~792Vac L-LCommunication: RS485,4G,WIFI,LoRa,LorawanHMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etcApplication Scenario: Building, Factory, Smart Grids, DB Room and etcStandard&Certificate: CE; IEC; LVD
Acrel ADL400N 3 Phase Multi-Function Energy Meter with CTs
● Measurement: 3-phase AC kWh, kVarh, U, I, P, Q, S, PF, F and etc
● Accuracy: 0.5% (kWh)
● Frequency: 45~65Hz
● Rated Voltage: 3x230~456Vac L-L ;3×110-265Vac L-N
● Rated Current: 3x80A AC,3x120A AC,3x200A,3×300 AC (via CTs)
● Communication: RS485 (MODBUS-RTU)
● Standard&Certificate: IEC; CE;CE-MID; EAC
Acrel ADW300 IOT Wireless 3 Phase Smart Energy Meter
Measurement: 3-phase Active Power, Reactive Power, Current, Voltage, Harmonic and etc.Rated Current: 3x1(6)A AC (via CTs)Rated Voltage: Up to 3x660~792Vac L-LCommunication: RS485,4G,WIFI,LoRa,LorawanHMI Programming: Setting of CT/PT Ratio, Phase Wiring, Communication and etcApplication Scenario: Building, Factory, Smart Grids, DB Room and etcStandard&Certificate: CE; IEC; LVD
Acrel ADW210 Multi-Channel Wireless 3 Phase Energy Meter
Measurement: Up to 4-channel 3-phase kWh, kVarh, Current, Power, 2~31st Harmonic and etcVoltage Rating: 3x220V/380V AC (3P4W)Current Rating: 5A, 100A, 400A or 600A AC (with external CTs)Frequency: 45~65HzCommunication: RS485 (MODBUS-RTU)Display: LCD
Acrel ADW200 Multi-Chanel 3 phase Energy Meter
● Mearsure up to 4 circuit 3 phase
● Mearsure all electric parameters
● Split core open loop CTs
● External function module, such as MK(switching inputs and outputs), MTL(temperature measurement and leakage current measurement), AWT100(wireless communication)
Acrel AMC72L-DI DC Digital Current Meter LCD Display
Measurement: 1-circuit DC Current
Accuracy: 0.5%
Rated Current: 5A DC (direct connect); 0/4~20mA DC (via DC Sensor); 75mV (via Shunt)
Power Supply: 85~265V AC/DC
Communication: RS485 (MODBUS-RTU)
Alarm Output: Low&High Current Alarm
Analog Output: 4~20mA DC
DI/DO Function: 2-channel DI&2-channel DO
Standard&Certificate: CE Certificates