● Measurement: 3-phase AC Active Power (Range: 0~+866W)
 Accuracy: Class 0.5
● Input: 0~1A/0~5A AC and 0~100V/0~220V/0~380V AC
● Output: 4~20mA/0~20mA DC or 0~5V/0~10V DC or RS485 (MODBUS-RTU)
 Power Supply: 85~265V AC(50Hz) or 100~350V DC or 24V/48V DC
● Wiring: 3-phase 4-wire
 Applicaiton: Paired with PLC for Industrial Automation; Used for Metering
● Response Time: ≤400ms
● Installation: 35mm DIN Rail/Screw fixed
● Standard&Certificate: CE
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description

Series Overview

 
 

Model Name

Measurement

Input

Output

Wiring

BA-AI

1-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU)

1-phase 2-wire

BA-3I3

3-phase

AC Current

0~1A AC/0~5A AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 3-wire

BA-AV

1-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

1-phase 2-wire

BA-3V3

 3-phase

AC Voltage

0~120/300/500V AC 

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC 

3-phase 3-wire

BA-4V3

 3-phase

AC Voltage

0~120/300/500V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

3-phase 4-wire

BD-DI

1-phase

DC Current

4~20mA DC/0~20mA DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire

BD-DV

1-phase

DC Voltage

0~75mV DC/0~10V DC

/0~300V DC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

1-phase 2-wire

BD-3P

 3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire

BD-4P

 3-phase

Active Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

BD-3Q

 3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire

BD-4Q

 3-phase

Reactive Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

BD-3/P/Q/I

 3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire

BD-4/P/Q/I

 3-phase

Active&Reactive

Power

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

BD-PF

3-phase

Power-Factor

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

BD-F

3-phase

Frequency

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

BD-3E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 3-wire

BD-4E

3-phase

Multi-Parameters

0~1A AC/0~5A AC

and

0~100/220/380V AC

4~20mA DC/0~20mA DC

0~5V DC/0~10V DC

RS485 (MODBUS-RTU) 

3-phase 4-wire

Dimension(unit:mm)

 
 

Model Name

Outline Size (mm)

L

H

D

W

M

BD-AI

138

76

24

35

120

BD-AV

138

76

24

35

120

BD-DI

138

76

24

35

120

BD-DV

138

76

24

35

120

Model Name

Outline Size (mm)

L

H

D

W

N

BD-3I3

110

75.4

128

35

111.7

BD-3V3

110

75.4

128

35

111.7

BD-4V3

110

75.4

128

35

111.7

Model Name

Outline Size (mm)

L

H

D

W

N

BD-3P

110

75.4

128

35

111.7

BD-4P

110

75.4

128

35

111.7

BD-3Q

110

75.4

128

35

111.7

BD-4Q

110

75.4

128

35

111.7

BD-3P/Q/I

110

75.4

128

35

111.7

BD-4P/Q/I

110

75.4

128

35

111.7

BD-PF

110

75.4

128

35

111.7

BD-F

110

75.4

128

35

111.7

BD-3E

110

75.4

128

35

111.7

BD-4E

110

75.4

128

35

111.7

Parameter

Technical parameters

Value

Accuracy class

0.5,0.2

 

 

 

 

Input

Nominal value

Current:AC、DC 1A、5A;

Voltage: AC、DC 100V、300V、500V and so on

Overload

Continual 1.2 times, Instantaneous current 10 times/5s;

Instantaneous voltage 2 times/30s;

Consumption

≤0.3VA(current input);

 Voltage input:

≤0.3VA(100V ),≤0.6VA(300V ),≤1VA(500V )

Frequency

50±5Hz, 60±5Hz

 

Output

 

Normal value

DC:4-20mA,0-20mA, 0-5V, 0-10V

Load resistance

Current output≤600Ω

Voltage output≥1000Ω

Ripple content

<0.5%(peak value)

Response time

≤400ms

Power supply

Voltage

AC85-265V、DC100-350V

Consumption

AC current, voltage≤3VA

Power≤4VA

Insulation resistance

 

≥100MΩ

Isolation voltage

(Among input//output//power supply)

2.0kV/1min, 50Hz

Temperature modulus

≤200ppm/℃

Environment

Temperature

Work:-10℃~+55℃; Storage: -25℃~+70℃

Humanity

In the place without dew and corrosive gas

Altitude

≤2000m

Fix mode

Rail, or fix to cubicle with bolt

 

Download

 