Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description
General
 
 

 

ACCU-100 Microgrid Coordination Controller is an intelligent coordination controller used in microgrid,distributed generation,energy storage and other fields.The device meets the requirements of the system to meet the access of photovoltaic systems,wind power generation,energy storage systems,charging piles and other equipment.Through all-weather data collection and analysis of the microgrid system,the operation status of photovoltaic,wind energy, energy storage system and charging piles is monitored.The health status of the microgrid is analyzed,and on this basis,the optimal control strategy is obtained with the goal of safe and economical optimal operation,and then the microgrid is implementedRegulation and control to achieve real-time dynamic regulation of microgrid distributed energy,energy storage system,and load,and promote local use of new energy.Improve grid operation stability and compensate for load fluctuations;effectively manage microgrid demand and improve microgrid operation.Improve operation efficiency,reduce power supply costs,and ensure safe,reliable and economical operation of microgrids.

 

Features
 
 

Multi-channel Data Acquisition

Serial/Ethernet real-time operation

Wind/solar/storage integration

Multi-protocol Communication

Modbus RTU/TCP, IEC 60870-5-101/103/104, MQTT

Cloud-edge collaboration (Acrel Cloud integration, remote OTA upgrades)

Local/remote switching & HMI (optional)

Edge Computing

Flexible alarm thresholds & active alerts

Data merging/logic control, breakpoint recovery

4G routing & data encryption

Strategy Customization

Anti-backflow, peak shaving/valley filling

Active/reactive power control, solar-storage coordination

Demand control & planning curve optimization

System Security

Untrusted model-based user permissions

Data authentication & anti-tampering mechanisms

Operational Safety

Full-station monitoring (battery, temperature, fire protection)

Early warning & predictive analytics

 

Product Parameter
 
 

project

Specification

processor

ARM Cortex-A7 528MHz

Memory

256MB DDR3 + 256MB NAND Flash

Frequency and power consumption

50Hz (45〜65Hz), power consumption ≤10W

Supply voltage

AC/DC 220V (85-265V)

RS485 Serial Port

8-way optocoupler isolation

RJ45Network port

2-way 10/100M adaptive

Other interfaces

1*RS232 management serial port + 1*USB2.0 +
SD Card standard slot + 4G interface; (DI, DO optional)

Protocol support

Device side: Modbus Rtu/TCP, DL/T 645-1997, DL/T 645, etc.;

Master side: Modbus TCP, 104, SNMP, MQTT protocol, etc.;

 

Security

Power frequency withstand voltage:
1 minute between power supply and communication terminals:
2kV (220V equipment), 1.5kV (24V equipment)

Insulation resistance:
Under normal test atmospheric conditions,
the input and output terminals to the housing> 100MΩ

 

 

Working temperature: -20℃〜+55℃

environment

Storage and transportation temperature: -25℃〜+70℃

Relative humidity: ≤95% (+25℃)

 

 

Altitude: ≤2500m

 

GB/T 17626.2-2018 Electrostatic discharge immunity test Level 4

Electrical properties

GB/T 17626.3-2016 Radio frequency electromagnetic field radiation immunity test Level 3

GB/T 17626.4-2018 Electrical fast transient burst immunity test Level 4

 

 

GB/T 17626.5-2019 Surge (impact) immunity test Level 4

 

System Architecture
 
 

 

ACCU-100Coordination controller:Control the output of energy storage equipment,distributed energy,and adjustable load equipment.According to the economic benefit model,the photovoltaic storage replacement can be carried out under the premise of meeting the dispatching requirements,reducing abandoned light.And interact with the cloud platform and respond to cloud policy configuration.

EMS3.0,a smart energy management cloud platform,meets the access of cross-site and cross-regional massive data,realizes the calculation and control of resources,electricity,loss,indicators,maintenance,and contribution indicators of each site through data analysis,and analyzes the trend of power generation and consumption through diversified forecasting,and provides the best control scheme in combination with electricity price data,production plan,and load demand.At the same time,it provides remote monitoring and operation and maintenance functions.

 