Acrel ADL3000-E Three-Phase Zero Export Energy Meter

● Measurement: 3-phase kWh (0.5S), Active Power, Reactive Power, Current, Voltage, Harmonic and etc

● Voltage Rating: 3x220/380V, 3x57.7/100V (3P4W); 3x380V, 3x100V (3P3W)

● Current Rating: 3x10(80)A; 3x1(6)A

● Frequency: 45~65Hz

● Commnunication: RS485 (MODBUS-RTU) and Infrared

● Multi-rate: Spike, Peak, Valley and Flat kWh

● Extra Function: Cable Temperature Measurement and DO/DI

● Display: LCD (8 digits)

● Dimension: 127*88*70mm (L*W*H)

● Wiring: 3-phase 4wire; 3-phase 3-wire

● Installation: 35mm DIN Rail

● Standard&Certificate: IEC; CE; EAC

description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description
General
 
 

ADL3000-E three-phase power meter is designed for 3-phase power measurement on low voltage system. The meter strictly follow the compliance of IEC62053-21,IEC62053-22 standards.

 

Model description
 
 

 

 

 

LCD display
 
 

 

  • Current forward active energy 12.34kWh
  • Current reversing active energy 12.34kWh
  • Current forward reactive energy 12.34kWh
  • Current total power is 1.234kW
  • Voltage on A phase is 123.4V
  • Current on A phase is 12.34A

Note: There are parts of the display function, and other menus are familiar with the example above. The customers can understand the meaning refer to the above examples.

 

Function
 
 

 

Function

Function description

Function provide

 

Measurement of kWh

Active kWh (positive and negative)

Reactive kWh (positive and negative)

A, B, C phase positive active kWh

Measurement of electrical parameters

U、IP、Q、S、PF、F

Measurement of

2~31ST Voltage and current harmonic

□Note 1

LCD Display

8 bits section LCD display, background light

Key programming

4 keys to communication and set parameters

Pulse output

Active pulse output

Reactive pulse output

Clock pulse output

Functions

Active switch input

Communication

Infrared communication

The first communication path: Communication interface: RS485,
Communication protocol: MODBUS-RTU 

“■” means standard, “□” means optional.

Note: Harmonic is a standard while choosing outlay transformer, optional for another situation.

 

Product Parameter
 
 

 

ADL3000-E-A

Specification

3 phase 4 wires, Earthed

Voltage

Reference voltage

3~66/115V、3~220/380V、3~277/480V(Three sizes)

Input voltage tolerance

3~66/115V、3~220/380V:±30%

3~277/480V:±10%

Consumption

<10VA (Single phase)

(Rate current or power for power input <10VA(Single phase))

Impedance

>2MΩ

Accuracy class

 Error±0.2%

Current

Input current

3~1(6)A

Min:0.01A,Standard:1A,Max:6A

Consumption

<1VA (Single phase rated current)

Accuracy class

 Error±0.2%

 Power

Active, reactive, apparent power, error±0.5℅

 Frequency

45~65Hz, Error±0.2%

 Energy

Active energy (Accuracy class:0.5, 1), reactive energy (Accuracy class 2)

Energy pulse output

1 active optocoupler output, Resistive load
(Voltage is not more than 24V, current is not more than 5mA)

Switching input

1 optocoupler input,Maximum allowed voltage: 220V,

OVC III

Measurement category

CAT III

Width of pulse

80±20ms

Pulse constant

6400imp/kWh

Interface and communication

RS485:Modbus RTU

Range of communication address

Modbus RTU:1~ 247;

 Baud rate

1200bps~19200bps

Working temperature

-25℃~+55℃

Relative humidity

≤95℅ (No condensation)

 Altitude

≤ 2000m

Installation environment

Indoor use

Pollution degree

Class 2

 

ADL3000-E-B

Specification

3 phase 4 wires, Earthed

Voltage

Reference voltage

3~66/115V、3~220/380V、3~277/480V(Three sizes)

Input voltage tolerance

3~66/115V、3~220/380V:±30%

3~277/480V:±10%

Consumption

<10VA (Single phase)

(Rate current or power for power input <10VA(Single phase))

Impedance

>2MΩ

Accuracy class

 Error±0.2%

Current

Input current

3~1(6)A

Min:0.01A,Standard:1A,Max:6A

Consumption

<1VA (Single phase rated current)

Accuracy class

 Error±0.2%

 Power

Active, reactive, apparent power, error±0.5℅

 Frequency

45~65Hz, Error±0.2%

 Energy

Active energy (Accuracy class:0.5, 1), reactive energy (Accuracy class 2)

Energy pulse output

1 active optocoupler output, Resistive load
(Voltage is not more than 24V, current is not more than 5mA)

Switching input

1 optocoupler input,Maximum allowed voltage: 220V,

OVC III

Measurement category

CAT III

Width of pulse

80±20ms

Pulse constant

6400imp/kWh

Interface and communication

RS485:Modbus RTU

Range of communication address

Modbus RTU:1~ 247;

 Baud rate

1200bps~19200bps

Working temperature

-25℃~+55℃

Relative humidity

≤95℅ (No condensation)

 Altitude

≤ 2000m

Installation environment

Indoor use

Pollution degree

Class 2

 

Dimension
 
 

 

 

Wiring
 
 

 

ADL3000-E-A

Three phase four lines direct connect

Note :

ADL3000-E-A can adopt one access methods: three-phase four wire .

 

product drawing

 

Port

Description

Remark

L1

UA Volatge Input /IA Currten Input

 

L1’

IA Currten Output

 

L2

UB Volatge Input /IB Currten Input

 

L2’

IB Currten Output

 

L3

UC Volatge Input /IC Currten Input

 

L3’

IC Currten Output

 

N

Neutral Line

 

ADL3000-E-B

Three phase four lines connect via CT

Note :

1.ADL3000-E-b can adopt one access method: three-phase four wire.

2.One end of the transformer needs to be grounded.

 

Packing&delivery
 
 

 

Download

  • Manual of ADL3000-E-A.pdf
  •  
  •  
  •  
  •  

  • Manual of ADL3000-E-B.pdf
  •  
  •  
  •  
  •  

  • UL Certificate-ADL3000.pdf
  •  
  •  
  •  
  •  