Acrel AMB100 Series Data Center Busway Monitoring Module

   

  • 2 dry-contact inputs
  • 45-65Hz
  • 3x220/380VAC
  • DIN 35 mm
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description
General
 
 

AMB Smart Alternating-current Bus Bar Monitor is a new development to cater for smart power bus bar. It consists of a feeding detection module and a tapping detection module and integrates functions of conventional power measurements, electricity monitoring, consumption assessment and control. It also boasts the online alarm function and enables the independent off-line operation. It monitors the bus bar interface temperature in real time.

Dimension(unit:mm)
 
 

Schematic Diagram
 
 

Wiring
 
 

Network
 
 

Site Application Photos
 
 

Technical Parameters

   

Measured parameters

Voltage, current, frequency, active power, inactive power,power factor, active energy,

inactive energy,

2nd-63rd harmonic, temperature, leakage

 

 

Voltage

Rated value

3x220/380VAC

Range

±20%

Overloading

1.2 times than the rated voltage value continuously or 2

times than the rated voltage value instantaneously per

second

 

 

 

Current

CT

AMB100-A: 5A/2.5mA, 100A/20mA, 400A/100mA,

600A/100mA

AMB110-A: 100A/20mA

Range

1%-120%

Overloading

1.2 times than the rated current value continuously or

10 times than the rated current value instantaneously per second

Input frequency

45-65Hz

Measurement accuracy

Voltage/current:grade 0.2; active power/energy:grade

0.5; inactive power/energy:grade 1; temperature:±1℃

Auxiliary power supply

AMB100/110-A(/W):triggered upon receipt of request

signal

AMB100/110-A(/W)-P1:follow the bus bar voltage

 

 

 

Functions

Temperature

detection

-20-150℃

Leakage

0-1A

Digital input

2 dry-contact inputs

Digital output

2 relay outputs; contact capacity :3A/30VDC,

3A/250VAC

Communication

Via RS485/Modbus-RTU or LORA antenna

Installation

Use DIN35mm rail

Protection

IP20

Pollution level

2

Environment

Temperature/

humidity/

altitude

 

Working temperature:-20-60℃

Storage temperature:-25-70℃

Relative humidity:≤93%

Altitude:≤2500m

 

Safety

Insulation

The minimum insulation resistance between all terminals

and conductive components of the shell is 100MΩ.

Withstanding

voltage

When a voltage of 2kV AC is applied between the

voltage/ current input, relay output, RS485 port, auxiliary power supply and digital inputs,

the leakage shall be less than 2mA and no breakdown or flashover shall occur in 1min.

Electromagnetic

immunity

Electrostatic

discharge

immunity

Class 4

Radio frequency

electromagnetic

immunity

Class 3

Transient burst

immunity

Class 4

Surge immunity

Class 4

Download
  • AMB Manual