Acrel ASCB1-63-C16 1P Smart Circuit Breaker

   

  •  Over Current / Power / Temp. Protection;
  •  Over / Under Voltage Protection;
  •  Short Circuit Protection;
  •  Leakage Current Protection.
description1
Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Description

Function

 
 

ASCB1 Series Intelligent MCB Function
* Can monitor voltage, current, power, power and temperature in real time
* with over-pressure, under-pressure, overload, short circuit, over-current, and over-temperature and other protection functions
* With local manual lever, local electric control, local lock, remote control, timing control and other control function
* Guide rail type installation, optional pole number 1P / 2P / 3P / 4P
* Standard RS-485 (MODBUS) communication; optional buckle curve type C / D

Wiring Diagram

 
 

 

  • Connect the RS485 port on the gateway to the BUS port of the circuit breaker by using the communication cable provided by the gateway.
  • Step2: Insert the barbed side of the connecting wire of the circuit breaker into the external terminal of the previous circuit breaker toward the outside of the terminal, and the colors need to be matched one by one.

 

 

Network Diagram

 
 

 FAQ

 
 

Q: Can the circuit breaker data be collected through RS485 communication?

A: The circuit breaker has its own RS485 communication interface, and it does not need to be equipped with an ASCB1-M gateway to access the customer system, but the customer needs to provide the circuit breaker with DC12V 12A auxiliary power supply

Q: How many circuit breakers can a gateway carry?

A: 16PCS

Q: How Gateways and Circuit Breakers are Networked?

A: The gateway and the circuit breaker are connected by a 4pin cable, a set of DC12V auxiliary power supply, and a set of RS485 communication lines.

The connection between the circuit breaker and the circuit breaker is the same.

One-key addressing operation through the gateway

Q: Does the circuit breaker need to be equipped with additional accessories?

A: 1. Internally integrate various sensor modules, including: current sensor, leakage transformer, temperature sensor, etc.;

  1. The circuit breaker integrates the release function, which can realize remote opening and closing operations;
  2. Configure the circuit breaker network cable
Technical Parameters

Model

ASCB1-63

ASCB1LE-63

Pole

1P/2P/3P/4P

2P/4P

Grade of Shell

63A

Rated Voltage

230V(1P/2P)、400V(3P/4P)

Rated Current

6A,10A,16A,20A,25A,32A,40A,50A,63A

Instantaneous Unbuckle Type

C/D

Rated Short-circuit Breaking Capacity

6000A

 

 

 

 

 

 

 

 

Protect

Over-current Protection

Default 100% rated current alert,

110% Rated current trip with adjustable threshold

Short-circuit Protection

5-10 Rated current for 0.04 seconds for circuit break protection

Overload Protection

Default 100% rated power alert,110% Rated power trip with adjustable threshold

Over-voltage Protection

Default 110% rated voltage alert,120% rated voltage trip with adjustable threshold

Under-voltage Protection

Default 90% rated voltage alert,80% rated voltage trip with adjustable threshold

Over-temperature Protection

Default 80℃ alert,100℃ trip, the threshold is adjustable

Leakage Protection

No

Default 20mA alert, 30mA trip, the threshold is adjustable

Leakage self-Inspection

No

Manual button self-inspection

Mechanical Life

20000 times

Electrical Life

6000 times

Levels of Protection

IP20

Connection Capacity

1-35mm²

Elevation Requirements

2000m

Ambient Temperature

-10℃~55℃,the average temperature at 24h was no higher than 40℃

Environmental Requirements

No explosion hazard, no conductive dust, no sufficient corrosion of

metal and damaged insulation, no significant vibration

Relative Humidity

At + 40℃, the relative humidity of the air is 50% and can have high

relative humidity at lower temperatures

Storage Temperature

-20℃-70℃

Class of Pollution

Installation Type

Way to Installation

Standard 35mm guide rail installation

Download
  • ASCB1 Manual

CONTACT US